VECTOR VFD • STO • ENCODER/PG • ANTI-SWAY • SYNC TRAVEL
Crane Inverters (VFD)
Vector drives for hoist, trolley and bridge. STO safety, encoder feedback, anti-sway & synchronized travel. Builder sizes braking resistor or regen unit, estimates heat load and gives a budget price.
- 380/415/440/460V
- STO SIL2/3*
- Encoder / Sensorless
- DBR / Regen
*Budgetary only. Final SIL/STO, thermal and EMC to be validated at proposal stage.
- IEC 61800 Practices
- CE/ISO
- 2-Year Warranty
- FAT & Docs
Smooth Motion
Vector control, S-curve ramps, torque boost, precise inching.
Safety Ready
STO input, brake logic, overload & thermal protection.
Smart Options
Encoder/PG card, anti-sway, synchronized long-travel.
Energy Handling
Dynamic-brake resistor or line-regen unit sizing guide.
Built for Heavy Duty Hoisting & Precise Positioning
- Hoist-grade control: fast torque response with brake interlock & motor thermistor.
- Travel efficiency: speed-sync for twin drives, creep speeds for alignment.
- Maintenance-friendly: fault logs, removable terminals, copy stick parameters.
- EMC & durability: chokes/filters, conformal coating options for harsh sites.
Build Your Spec
VFD Snapshot
- Total kW
- — kW
- Braking
- —
- Suggested DBR / Regen
- —
- Heat Load
- — W
- Functions
- —
- EMC
- —
- Supply / IP
- —
- Status
- OK
- Qty / Timeline
- 1 / —
Heat ≈ VFDkW × 3.5% (sensorless) or 3.2% (encoder).
DBR continuous power (budget) ≈ HoistkW × duty-factor × 0.6;Regen module ≈ TotalkW × (0.3–0.5) by duty.
Budget Estimate
Auto‑updates from “Build Your Spec”. Budgetary range (ex‑works). Final quote after drawings & duty confirmation.
- Power & Supply
- —
- Braking/EMC
- —
- Functions
- —
- Quantity
- —
- Timeline
- —
Applications & Examples
Technical Specifications
| Motions | Hoist, trolley and bridge (single/twin drives) |
|---|---|
| Control | Vector (encoder/sensorless), S-curve, torque boost, brake logic, inching |
| Safety | STO input; motor thermistor; e-stop chain integration |
| Functions | Anti-sway algorithm, speed synchronization, master-follower |
| Energy | Dynamic braking resistor or line-regenerative unit |
| EMC/Line | Line reactor or RFI filter; DC chopper as required |
| Supply | 380–460V, 50/60Hz, 3Ph |
| IP/Env | IP54–IP65; options for hot/cold/dusty environments |
| Docs & Tests | Parameter list, I/O map, FAT report on request |
From Inquiry to Commissioning
- 01 · SizingkW, duty & functions
- 02 · ProposalLayout & budget
- 03 · AssemblyDrives & options
- 04 · FATParameter & function tests
- 05 · CommissionOn-site setup
Get Pricing & Lead Time
Tell us kW by motion, braking mode (DBR/regen), encoder/anti-sway/sync, supply & environment. We’ll return drawings and a firm quote.
Note
Calculator is for discussion; final selection validates STO level, thermal, braking energy and EMC.